One-component modified polyurea coating

BW6-9528 One-Component Modified Polyurea Waterproof Anticorrosion Protective Coating

BW6-9528

Hand-applied waterproof, anticorrosion and protective coating for roofs, balconies, basements, old SBS membranes and color steel tile renovation.

BW6-9528 is a one-component aromatic-modified polyurea coating with high elasticity, strong adhesion and simple application by brush, roller or high-pressure airless spraying without specialized polyurea spray equipment.

Product description

BW6-9528 one-component modified polyurea waterproof anticorrosion protective coating.

Use BW6-9528 when a project needs hand-applied waterproofing, anticorrosion protection and strong substrate adhesion on roofs, balconies, bathrooms, exterior walls, basements, old SBS membrane roofs or color steel tile roofs.

BW6-9528 One-Component Modified Polyurea Waterproof Anticorrosion Protective Coating official product packaging image

What BW6-9528 delivers for renovation waterproofing

The formulation is designed for flexible waterproof and anticorrosion protection where brush or roller application is more practical than professional polyurea spray equipment.

  • One-component handlingNo component ratio mixing is needed, reducing labor complexity for repair and renovation work.
  • Brush, roller or airless applicationThe data sheet states that professional polyurea spraying equipment is not required.
  • Roof and balcony waterproofingHigh elasticity, good flexibility and strong leakage resistance support exposed building waterproofing projects.
  • Old SBS roof repairThe application scope especially highlights renovation of old SBS membrane roofs.
  • Color steel tile protectionSuitable for anticorrosion waterproofing treatment of old profiled color steel tile roofs.
  • Concrete and steel adhesionExcellent adhesion supports quick, firm bonding to concrete, steel, wood and glass fiber substrates after proper preparation.

Buyer-focused advantages for roof and repair projects.

Combine the key measured properties from the BW6-9528 data sheet with the highest-intent repair applications buyers ask about.

17 MPaTensile strength. ASTM D-412 test result for BW6-9528 supports flexible protective coating performance.
400%Elongation. ASTM D-412 elongation result supports crack-bridging and movement tolerance in waterproof repair work.
RoofRoof waterproof repair. Suitable for hand-applied waterproof protection on building roofs, balconies and repair details.
SBSSBS membrane repair. Especially applicable to renovation and repair of old SBS membrane material roofs.

Application scope

Typical use areas for BW6-9528.

The source data sheet positions BW6-9528 for construction, water conservancy, transportation, chemical, electricity and similar waterproof anticorrosion protection projects.

Building waterproofing

  • Roof waterproofingFor building roof waterproof protection and renovation details where hand application is preferred.
  • Balcony and bathroom waterproofingSuitable for balconies, bathrooms and wet-area details listed in the data sheet.
  • Basement and exterior wall waterproofingSupports basement and exterior wall protection after substrate preparation and adhesion review.

Renovation and anticorrosion

  • Old SBS membrane roof repairEspecially applicable to renovation of old roofs constructed with SBS membranes.
  • Old color steel tile roofsUsed for anticorrosion and waterproofing treatment of old profiled color steel tile roofs.
  • Water conservancy and industrial protectionCan be reviewed for dams, hydropower station buildings, transportation, chemical and electricity projects.

Product information & technical data

Technical data for BW6-9528 modified polyurea waterproof anticorrosion coating.

Review product information, physical properties, chemical resistance and application data for procurement and project compatibility checks.

Product information

ItemResult
AppearanceColor is adjustable
Specific gravity (g/cm3)1.25 +/- 0.05
Viscosity (cps) @ 20°C7500 +/- 500
Solid content (%)≥80
Surface dry time (h)2-4
Pot life (h)1
Theoretical coverage0.75 kg/m2 at 500 µm thickness

Physical properties

ItemTest standardResult
Hardness (Shore A)ASTM D-224078
Elongation (%)ASTM D-412400
Tensile strength (MPa)ASTM D-41217
Tear strength (kN/m)ASTM D-62452
Abrasion resistance (750 g / 500 r), mgHG / T 3831-200610
Adhesive strength (MPa), steel baseHG / T 3831-20068
Adhesive strength (MPa), concrete baseHG / T 3831-20063.3
Impact resistance (kg.m)GB / T 23446-20091.0
Density (g/cm3)GB / T 6750-20071.25

Chemical resistance

For reference: pay attention to ventilation, splash and spillage. Independent immersion testing is recommended if detailed data is required.

Exposure itemResult
Acid resistance 10%H2SO4 or 10%HCl, 30 dNo rust, no bubbles, no peel off
Alkali resistance 10%NaOH, 30 dNo rust, no bubbles, no peel off
Salt resistance 10 g/L, 30 dNo rust, no bubbles, no peel off
Salt spray resistance, 2000 hNo rust, no bubbles, no peel off
Oil resistanceNo bubbles, no peel off
0# diesel, crude oil, 30 dNo rust, no bubbles, no peel off

Application guide

Application conditions and instructions.

Confirm site temperature, humidity, dew point, substrate preparation, coating thickness and recoating interval before applying BW6-9528.

Application environment

Confirm temperature, humidity and dew point before application, especially on metal surfaces.

ConditionRequirement
Environment temperature-5 to 35°C
Relative humidity35-85%
Dew pointWhen applying on metal surfaces, the surface temperature must be at least 3°C higher than the dew point temperature.

Application instructions

BW6-9528 is designed for brush, roller or high-pressure airless application without specialized polyurea spray equipment.

Guide itemRecommendation
Recommended dry film thickness300-1000 µm, or as design requirements
Recoating interval4-24 h. If recoating exceeds 24 h or the surface has dust, sand and clean before application.
Recommended coating methodsBrush, roller or high-pressure airless spraying. No specialized polyurea spraying equipment is required.
Before useStir the coating evenly before use, pour out only the required quantity and close the barrel lid quickly.
Diluent controlDo not add diluent without permission. If viscosity adjustment is needed because of temperature or site conditions, consult the manufacturer before adding special diluent.

Substrate treatment

Prepare each substrate according to the data sheet before full application or recoating.

SubstrateTreatment requirement
Metal surfaceSandblast for rust removal to Sa2.5 according to ISO8501-1 or GB8923.
Concrete surfaceFirm, dense, flat, clean and dry. No sanding, peeling, cracks or honeycomb pits; repair with putty where needed.
Wood surfaceClean, dry and free from burrs, debris and loose fragments.
Other substratesConsult BW technical personnel for surface treatment guidance.

Application tips

NoteInstruction
Low-temperature useBW6-9528 can be used at -5°C. In low-temperature environments, place the coating bucket in an air-conditioned room for at least 24 hours before use.
Before each useStir the coating evenly, pour out the exact quantity needed and quickly close the barrel lid.
Material handlingDo not return used material to the original barrel, and do not add diluent without technical confirmation.

Curing time, shelf life and packing

Curing time, storage and packing information for project planning.

Use the curing profile and storage information below to plan roof, balcony, basement or color steel tile repair timing, handling and purchasing.

Product curing time

Note: curing time varies with environmental conditions, especially temperature and relative humidity.

Substrate temperatureSurface dry timeFoot trafficSolid dry time
+10°C5 h24 h7 d
+20°C3 h16 h6 d
+30°C2 h8 h5 d

Shelf life & packing

ItemDetails
Package5 kg/barrel; 25 kg/barrel
Shelf life6 months, sealed
Storage temperature5-35°C
Storage precautionStore in a cool and ventilated place, avoid direct sunlight and keep away from heat.

Health & safety / integrity declaration

Safety data, handling guidance and application verification.

Product health and safety information

For information and advice on safe handling, storage and disposal of chemical products, users should refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data.

Integrity declaration

All technical data in this sheet is based on laboratory tests. Actual testing methods may vary under different circumstances, so project teams should test and verify suitability before full application.

FAQ

FAQ about BW6-9528 hand-applied modified polyurea coating.

These answers follow the BW6-9528 data sheet and focus on hand-applied waterproof anticorrosion repair planning before ordering.

What is BW6-9528 mainly used for?

BW6-9528 is a one-component aromatic-modified polyurea waterproof and anticorrosion protective coating for building roofs, balconies, bathrooms, exterior walls, basements, water conservancy dams and hydropower station buildings. The data sheet especially highlights old SBS membrane roof repair and anticorrosion waterproofing of old profiled color steel tile roofs.

Does BW6-9528 require professional polyurea spraying equipment?

No. The data sheet states that BW6-9528 does not require specialized polyurea spraying equipment. Recommended coating methods are brush application, roller application or high-pressure airless spraying.

Is BW6-9528 a one-component material?

Yes. BW6-9528 is a one-component material, so it is easy to apply without component ratio mixing. The data sheet still recommends stirring the coating evenly before use and pouring out only the amount that will be used.

What dry film thickness and recoating interval are recommended?

The data sheet recommends 300-1000 micrometers dry film thickness, or the project design requirement. The recoating interval is 4-24 hours. If recoating exceeds 24 hours or the surface has dust, sand and clean the surface before applying the next coat.

What substrates are listed for BW6-9528?

The product has excellent adhesion to concrete and steel substrates and can bond to concrete, steel, wood and glass fiber surfaces. Metal surfaces should be sandblasted to Sa2.5, concrete should be firm, dense, flat, clean and dry, and wood should be clean, dry and free from burrs and loose debris.

Can BW6-9528 be used in low-temperature conditions?

The application environment range is -5 to 35 degrees Celsius, and the data sheet says the product can be used at -5 degrees Celsius. In low-temperature environments, place the coating bucket in an air-conditioned room for at least 24 hours before use.

Request technical documents

Request TDS, application guidance or bulk project support.

If you are evaluating BW6-9528 for roof waterproofing, balcony repair, basement protection, old SBS membrane renovation or color steel tile anticorrosion waterproofing, request the latest technical data sheet, application guidance and project-specific compatibility review before ordering.