Concrete leakage grouting plugging agent

BW6-190 One-Component Polyurea Elastomer Grouting Plugging Agent

BW6-190

Hydrophilic one-component polyurea elastomer grouting material for concrete crack leakage repair.

After pressurization by a grouting machine, BW6-190 penetrates concrete microcracks and reacts with water or moisture in the crack, expanding rapidly to form a tough polymer elastomer for waterproof anti-leakage protection.

Product description

BW6-190 hydrophilic polyurea elastomer grouting plugging agent.

BW6-190 is prepolymerized with amine-terminated polyether and isocyanate as the main resins. It is designed to enter concrete cracks under grouting pressure, react with water or moisture and form a high-toughness elastomeric plugging body.

BW6-190 One-Component Polyurea Elastomer Grouting Plugging Agent official product packaging image

What BW6-190 delivers for leakage grouting repair

The formulation focuses on leak plugging inside concrete cracks: penetration, reaction with water, rapid expansion, elastic sealing and durable waterproof reinforcement.

  • Elastic waterproof pluggingAfter reacting in the crack, the material forms a high-toughness, high-strength polymer elastomer for anti-leakage protection.
  • Microcrack penetrationThe data sheet positions BW6-190 for concrete microcracks less than 0.2 mm and capillary pores.
  • Rapid water reactionIt reacts readily with water or moisture and expands more than tenfold quickly after reaction.
  • Wet-crack suitabilityThe product can cure in water, has good fluidity and can react with weak acid or alkaline water without affecting plugging effect.
  • Deformation toleranceHigh strength and outstanding elasticity help the cured material adapt to structural deformation.
  • Simple one-component handlingSingle-component, solvent-free material listed as odorless, non-toxic and free of VOC emissions in the source data sheet.

Technical advantages for elastic leakage plugging and crack grouting.

These buyer-facing points come from the BW6-190 source data sheet and focus on concrete leakage repair, crack grouting and elastic waterproof plugging.

<0.2 mmMicrocrack target. Designed to rapidly block fine concrete cracks and capillary pores that are difficult to treat from the surface.
10x+Expansion in cracks. Reacts with water or moisture and expands more than tenfold to fill leakage paths.
800-900%Foaming rate. Technical table value for purchasing and repair-method review.
30-60 minCuring time. Reference curing window from the English technical data table.

Application scope

Typical use areas for BW6-190.

BW6-190 is used for concrete structure leakage grouting and plugging where water is entering through cracks, pores or joints.

Concrete leakage scenarios

  • Basements and underground spacesFor leakage grouting in large building basements, utility tunnels and civil villa basements.
  • Tanks and water-retaining structuresFor large concrete drinking water tanks and sewage tanks where crack leakage requires pressure grouting.
  • Tunnels, culverts and subwaysFor underground infrastructure leakage plugging where grouting needles can reach active crack paths.

Repair planning checks

  • Crack path confirmationClean the crack, observe overflow during water injection where possible and add needles where grout paths are incomplete.
  • Needle spacing and angleUse 45 degree inclined drilling on both sides of the crack, typically one needle every 10-15 cm.
  • Supplement until dryInsufficiently filled sections should receive extra grouting needles until there is no water seepage.

Product information & technical data

Technical data for BW6-190 grouting plugging agent.

Review product information and data-sheet performance notes for concrete leakage plugging, crack repair and procurement comparison.

Product information

ItemResult
Solid content (%)90
Specific gravity (g/cm3)1.05
Curing time (min)30-60
Elongation at break (%)120
Foaming rate (%)800-900
Bonding strength (MPa)1.8

Performance notes

Buyer concernTDS guidance
Leakage plugging mechanismPenetrates concrete microcracks and reacts with water or moisture in the crack.
Expansion after reactionVolume expands more than tenfold quickly after reaction, forming a polymer elastomer.
Crack and pore targetDesigned to rapidly seal concrete microcracks less than 0.2 mm and capillary pores.
Elastic repair behaviorHigh strength and elasticity help the cured body adapt to structural deformation.
Water quality toleranceCan react with weak acid and alkaline water without affecting plugging effect.
Handling profileOne-component, solvent-free material with no VOC emissions listed in the data sheet.

Application scope summary

Use areaLeakage repair scope
Water and sewage tanksLeakage grouting for large concrete drinking water tanks and sewage tanks.
Building basementsLeakage grouting for large building basements and civil residential villa basements.
Underground infrastructureLeakage grouting for subways, tunnels, culverts and basement utility tunnels.
Toilets and facility leaksConcrete structure leakage grouting and plugging for toilets and related facilities.

Application guide

Grouting equipment and crack repair instructions.

Follow the source data sheet sequence: crack cleaning, 45 degree grouting needles, water-checking where possible, pressure grouting and supplementary grouting until seepage stops.

Application instructions

StepApplication instruction
01Grouting equipmentUse the same equipment used for traditional foamed polyurethane grouting; no need to replace the machine when changing materials.
02Substrate treatmentClean debris and dust on and around concrete cracks; ensure the surrounding concrete is firm and clean.
03Pre-embedded grouting needlesDrill inclined holes at a 45° angle along both sides of the crack. Hole depth must penetrate the crack. Set one needle every 10-15 cm and add a 45° needle at crack intersections.
04Crack cleaningIf conditions permit, inject water for crack cleaning and observe whether water overflows from the crack surface. Add needles where local areas do not overflow.
05Polyurea groutingPour the grouting agent into the hopper and start water-stop reinforcement grouting. Continue pressing for 2-3 seconds after the next needle exudes grout.
06Supplementary groutingEnsure cracks are fully filled. Add grouting needles for insufficiently grouted areas until there is no water seepage.

Shelf life & packing

ItemDetails
Packing specification5 kg/barrel; 10 kg/barrel
Shelf life from manufacturing date10 months in unopened original packaging
Storage temperature5-35°C
Package requirementKeep the product package tightly sealed
Storage precautionStore in a cool, ventilated place and avoid direct sunlight

Critical field notes

  • Keep the crack area firm and clean before drilling and grouting.
  • Confirm grout overflow and add needles where the crack path is not fully reached.

Storage and purchasing

Packaging, shelf life and handling information.

Use the packaging and storage data below to plan purchasing, warehouse handling and unopened shelf-life control.

Packing specification

BW6-190 is supplied as a one-component grouting material in 5 kg/barrel and 10 kg/barrel packaging according to the data sheet.

Storage conditions

Store sealed product at 5-35°C in a cool, ventilated environment and avoid direct sunlight. Shelf life is 10 months from production date when unopened and sealed.

Health & safety / integrity declaration

Safety data, handling guidance and application verification.

Product health and safety information

For information and advice on safe handling, storage and disposal of chemical products, users should refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data.

Integrity declaration

All technical data in this sheet is based on laboratory tests. Actual testing methods may vary under different circumstances, so project teams should test and verify suitability before full application.

FAQ

FAQ about BW6-190 grouting leakage repair.

These answers follow the BW6-190 data sheet and focus on grouting equipment, crack preparation and leakage plugging workflow.

What is BW6-190 used for?

BW6-190 is a one-component hydrophilic polyurea elastomer grouting plugging agent for concrete structure leakage, including microcracks, capillary pores, tanks, basements, tunnels, culverts, utility tunnels, villas and toilets.

What grouting equipment is used for BW6-190?

No. The application guide specifies grouting equipment like that used for traditional foamed polyurethane grouting, so teams can change material without changing the grouting machine.

How are grouting needles arranged for cracks?

The guide calls for inclined holes at a 45 degree angle along both sides of the crack. The hole depth should penetrate the crack, with one needle every 10-15 cm and an additional 45 degree needle at crack intersections.

Can BW6-190 react and cure in wet cracks?

Yes. The product reacts with water or moisture in the crack, expands rapidly after reaction and forms a high-toughness, high-strength polymer elastomer for waterproof leakage plugging.

What should be checked during crack cleaning?

If site conditions allow, inject water with a grouting machine to clean the crack and observe whether water overflows from the crack surface. Add grouting needles where local areas do not overflow.

When should grouting continue or stop?

During polyurea grouting, continue pressing for 2-3 seconds after the next grouting needle exudes grout. Areas with insufficient filling should receive additional needles and supplementary grouting until seepage stops.

Request technical documents

Request TDS, grouting guidance or project support.

If you are evaluating BW6-190 for concrete crack leakage repair, basement grouting, tanks, tunnels or other waterproof plugging work, request the latest technical data sheet and project-specific application review before ordering.