Single-component hand-scraped thick-film polyurea

BW6-9526 Hand-Applied Thick-Film Polyurea Waterproof Coating

BW6-9526

A single-component aromatic thick-film polyurea coating for waterproof, anticorrosion and wear-resistant repair work without specialized spray equipment.

BW6-9526 cures into a thick protective membrane with strong adhesion to concrete and steel. It is designed for scraper application, high-build waterproofing, chemical resistance and structural repair details such as cracks, expansion joints, dams, docks and building waterproofing areas.

Product description

BW6-9526 single-component hand-scraped thick-film polyurea waterproof anticorrosion wear-resistant coating.

The source data sheet describes BW6-9526 as a single-component aromatic thick-film polyurea coating that forms a thick protective membrane with excellent adhesion to concrete and steel, plus waterproofing, chemical resistance and mechanical strength for repair and protection projects.

BW6-9526 Hand-Applied Thick-Film Polyurea Waterproof Coating official product packaging image

What BW6-9526 delivers for hand-applied repair work

The formulation is built for field-friendly high-build coating work where teams need waterproofing, anticorrosion protection, wear resistance and crack or joint repair without plural-component spray equipment.

  • Single-component handlingNo two-component ratio setup is required, helping reduce site labor complexity for small and medium repair areas.
  • Scraper-applied thick filmThe sheet specifies scraper application and states that specialized polyurea spray equipment is not needed for one-time thick-film build.
  • Waterproof and anticorrosion protectionIts chemical structure supports waterproof performance and resistance to acids, alkali, salt, oil and organic solvent exposure listed in the data sheet.
  • Wear, impact and scratch resistanceShore A 88 hardness, 320% elongation, 60 kN/m tear strength and 8 mg abrasion resistance support demanding repair environments.
  • Strong substrate adhesionThe coating bonds to steel, concrete, wood, fiberglass and other substrates after suitable surface preparation.
  • Repair construction convenienceUse it for cracks, expansion joints, waterproofing details, dams, docks and maintenance locations where bringing spray equipment is not practical.

Technical advantages for hand-applied waterproof and anticorrosion repair.

Focus on the core job: single-component scraper application, thick-film waterproofing, anticorrosion protection, wear resistance and easier repair construction.

1KSingle-component handling. Easy-to-use material without ratio setup, helping reduce labor cost and simplify field repair work.
H2OWaterproof and anticorrosion. Designed for integrated waterproof and anti-corrosion protection, with listed acid, alkali, salt and oil resistance.
320%Elongation. High elongation supports flexible repair use around cracks, joints and movement-prone structural details.
19 MPaTensile strength. High mechanical strength supports tough thick-film protection over prepared concrete and steel substrates.

Application scope

Typical use areas for BW6-9526.

Use BW6-9526 where a hand-applied thick-film polyurea layer is needed for waterproofing, anticorrosion, wear-resistant protection or crack and leakage repair.

Waterproofing and repair

  • Building wall and roof waterproofingFor thick-film waterproofing details where scraper-applied polyurea is preferred over spray equipment.
  • Crack and expansion joint sealingSuitable for structural crack water stopping and expansion joint sealing after substrate preparation and site verification.
  • Dam, embankment and leakage repairThe source sheet lists water conservancy dams, coastal embankments and leakage-blocking repair applications.

Protective maintenance

  • Highway, pavement and runway crack repairListed for repair of highway asphalt pavement, cement pavement and airport runway cracks.
  • Harbor, dock and port maintenanceSupports anti-seepage and maintenance protection for harbor, dock and port environments.
  • Steel and concrete anticorrosionUse on prepared steel, concrete, wood or fiberglass where adhesion, waterproofing and chemical resistance are required.

Product information & technical data

Technical data for BW6-9526 hand-applied thick-film polyurea coating.

Review product information, physical properties, chemical resistance and application data before project selection or bulk purchasing.

Product information

ItemValue
AppearanceColor is adjustable
Specific gravity (g/cm3)1.1
Viscosity (cps) @ 20°C10000-30000
Solid content (%)≥80
Surface dry time (h)1-3
Pot life (h)0.5
Theoretical coverage0.72 kg/m2 at 500 µm thickness

Physical properties

ItemTest standardResult
Hardness (Shore A)GB / T 23446-200988
Elongation (%)GB / T 23446-2009320
Tensile strength (MPa)GB / T 23446-200919
Tear strength (kN/m)GB / T 23446-200960
Abrasion resistance (750 g / 500 r) mgHG / T 3831-20068
Adhesive strength (MPa) steel baseHG / T 3831-200610
Adhesive strength (MPa) concrete baseHG / T 3831-20063.3
Impact resistance (kg.m)GB / T 23446-20091.0
Density (g/cm3)GB / T 6750-20071.25

Chemical resistance

For reference: pay attention to ventilation, splash and spillage. Independent immersion testing is recommended if detailed data for a specific medium is required.

Exposure itemResult
Acid resistance 30%H2SO4 or 10%HCl, 30 dNo rust, no bubbles, no peeling
Alkali resistance 30%NaOH, 30 dNo rust, no bubbles, no peeling
Salt resistance 30 g/L, 30 dNo rust, no bubbles, no peeling
Salt spray resistance, 2000 hNo rust, no bubbles, no peeling
Oil resistance, 0# diesel and crude oil, 30 dNo rust, no bubbles, no peeling

Application guide

Application conditions and instructions.

Confirm temperature, humidity, dew point, substrate preparation and hand-scrape procedure before applying BW6-9526.

Application temperature

ConditionRequirement
Environment temperature-5 to +35°C
Relative humidity35-85%
Dew point on metal surfaceSubstrate temperature must be at least 3°C above dew point

Application instructions

Guide itemRecommendation
Application methodUse scraper to hand-scrape the coating; specialized polyurea spray equipment is not required
Recommended DFT500-1000 µm, or based on design requirements
Recoating interval4-24 h; if over 24 h or dusty, sand and clean before applying the next coat
Low-temperature handlingBelow 10°C, keep the coating bucket in an air-conditioned room for more than 24 h before application
Opened bucket handlingStir uniformly before each use, pour only the amount needed, seal promptly, and do not return poured-out material to the original bucket
Thinner controlDo not add thinner randomly; consult the supplier before using dedicated thinner for special site conditions

Application tips

ItemRecommendation
Substrate preparationMetal surfaces should be blasted to Sa2.5; concrete should be firm, dense, flat, clean and dry before coating.
Application methodApply by scraper; this product is not a spray-equipment default.
Opened bucket handlingStir the bucket evenly, pour only what is needed, seal promptly after use and avoid returning poured-out material to the original bucket.

Curing time, shelf life and packing

Curing time, storage and packing information for repair planning.

Use the curing profile, storage temperature and packaging information below to plan site timing, warehouse handling and purchasing.

Product curing time

Note: curing time varies with environmental conditions, especially temperature and relative humidity.

Substrate temperatureSurface dry timeFoot trafficSolid dry time
+10°C4 h24 h7 d
+20°C1.5 h8 h6 d
+30°C1 h6 h5 d

Shelf life & packing

ItemDetails
Shelf life from manufacturing date10 months, unopened original packaging
Storage temperature5-35°C
Package requirementKeep the product package tightly sealed
Storage precautionStore in a cool, ventilated place and avoid direct sunlight
Package4 kg/bucket; 15 kg/bucket

Health & safety / integrity declaration

Safety data, handling guidance and application verification.

Product health and safety information

For information and advice on safe handling, storage and disposal of chemical products, users should refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data.

Integrity declaration

All technical data in this sheet is based on laboratory tests. Actual testing methods may vary under different circumstances, so project teams should test and verify suitability before full application.

FAQ

FAQ about BW6-9526 hand-applied thick-film polyurea waterproof coating.

These answers follow the BW6-9526 source data sheet and support contractor review before ordering.

Does BW6-9526 require a specialized polyurea spray machine?

No. The data sheet states that BW6-9526 can be applied by scraper and does not require specialized polyurea spraying equipment, which is the main reason it is positioned for hand-applied thick-film repair work.

What is the recommended dry film thickness for BW6-9526?

The application guide lists a recommended dry film thickness of 500-1000 micrometers, or the project design requirement if a different build is specified.

Where is BW6-9526 typically used?

The data sheet lists waterproofing and repair work in construction, water conservancy, transportation, chemical and power plant projects, including highway, pavement and airport runway crack repair, dam and coastal embankment leakage repair, and harbor or dock maintenance.

What substrate preparation does BW6-9526 need?

For metal, the Chinese sheet recommends abrasive blasting to Sa2.5 according to ISO8501-1 or GB8923. Concrete should be firm, dense, flat, clean and dry, with loose sand, shelling, cracks, honeycombs or pitted areas repaired first. Wood should be clean, dry and free of burrs and loose fragments.

How should BW6-9526 be handled after opening?

The sheet advises stirring the coating uniformly before use, pouring out only the amount needed, sealing the bucket promptly, and not returning poured-out material to the original bucket to reduce moisture exposure.

Can thinner be added to BW6-9526 on site?

The data sheet says the viscosity is adjusted before shipment and thinner should not be added randomly. If temperature or site conditions require viscosity adjustment, the supplier should be consulted and a dedicated thinner used only after guidance is confirmed.

Request technical documents

Request TDS, application guidance or bulk project support.

If you are evaluating BW6-9526 for scraper-applied waterproofing, anticorrosion, crack sealing, dam, dock or concrete repair work, request the latest technical data sheet, application guidance and project-specific compatibility review before ordering.